site stats

Readytoprocess wave 25 system handbook

WebCytiva WebOct 18, 2013 · Posted on October 18, 2013. The single-use ReadyToProcess WAVE 25 bioreactor system is a reliable and intuitive cell culture device for working volumes up to 25 L. It is based on a wellknown rocking technology providing mixing and aeration to the culture, which is maintained in an inflated, disposable Cellbag™ bioreactor cultivation …

Used Wave Bioreactor for sale. GE Healthcare equipment & more

WebThe schematic diagram of WAVE 25 setup is presented in Fig. 2. WAVE 25 was equipped with a disposable pre-sterilized polymer-based 2.0-litre Cellbag TM (GE Healthcare, US), which is characterized ... 로제 on the ground https://all-walls.com

Effects of feeding strategy on CHO cell performance in fed …

Webthe ReadyToProcess WAVE 25 system at a target cell-specific perfusion rate of ~ 137.5 pL/cell/d. Adjustments to the perfusion rate were made every two hours based on assumed exponential growth rate, as programmed using the Method Editor function. The cultures were controlled at pH 7.1, 40% dissolved oxygen (DO), and a temperature of 36.8ºC. WebBioreactor cultures were performed in the ReadyToProcess WAVE 25 system operated in dual mode. Two 10 L Cellbag™ bioreactor bags for the duplicate cultures were place on the same rocker. Culture parameters are listed in Table 2. Cultures were controlled using the UNICORN™ system control software. http://landing1.gehealthcare.com/rs/005-SHS-767/images/GE_Madhu-Raghunathan_GE-SU-Symposium_01-Nov-16.pdf on the ground counseling

Ge ReadyToProcess WAVE 25 Manuals ManualsLib

Category:GE总代理-GE总代 GE全国销售代理 GE上海代理-GE全国代理-化工 …

Tags:Readytoprocess wave 25 system handbook

Readytoprocess wave 25 system handbook

Ge ReadyToProcess WAVE 25 Manuals ManualsLib

Webcompare the performance of ReadyToProcess WAVE 25 with that of XDR-200, 7 L of the 200 L culture was transferred to a parallel ReadyToProcess WAVE 25 system to a total culture volume of 10 L. MAb yields from the parallel productions were 5.0 and 4.9 g/L for XDR-200 and ReadyToProcess WAVE 25, respectively. The metabolite WebThe ReadyToProcess WAVE 25 system consists of a rocker (ReadyToProcess WAVE 25 Rocker), control units (ReadyToProcess CBCU), and pumps (ReadyToProcess Pump 25), …

Readytoprocess wave 25 system handbook

Did you know?

WebOct 18, 2013 · ReadyToProcess WAVE 25 offers the following benefits: • Robust and reliable performance • Intelligent and accurate process control • Designed for ease of use • … WebBioreactor Systems. - Brochure. The single‑use ReadyToProcess WAVE™ 25 rocking bioreactor system is a reliable and intuitive cell culture system for working volumes up to …

WebFeb 4, 2024 · 2 System description 2.2 ReadyToProcess WAVE 25 rocker ReadyToProcess WAVE 25 User Manual 29009598 AD 21 Step Action 2 Hold the textured grip area on each … WebThe function of a given pump head is set in the UNICORN software. Up to three pump units are supported in both single and dual mode. For specifications of the pump, refer to the …

WebThe schematic diagram of WAVE 25 setup is presented in Fig. 2. WAVE 25 was equipped with a disposable pre-sterilized polymer-based 2.0-litre Cellbag TM (GE Healthcare, US), … WebThe CBCU is a component of the ReadyToProcess WAVE 25 bioreactor system. It provides gas to the culture, and monitors pH and/or dissolved oxygen. The compact system contains a controller for mass flow, sensors for gas pressure and O₂ and CO₂ concentrations, and transmitters for pH and DO. An optical fiber cable (Bag Sensor Adaptor 2.5m Assy ...

WebSee the ReadyToProcess WAVE 25 System Handbook for details. Connect to mains power Step Action. 1 Connect the supplied power cord between the power inlet on the rear panel of the rocker and a grounded power outlet. 2 Follow the manufacturer's instruction to connect power to computer, monitor ...

http://landing1.gehealthcare.com/rs/005-SHS-767/images/BPIEAST-ScalableAdenovirus.pdf on the ground downloadWebSystem overview ReadyToProcess WAVE™ 25 system components The ReadyToProcess WAVE™ 25 system consists of a rocker, CBCU gas mixers, and pumps, all operated by the … onthe groundWebFor system and component specifications, wetted materials and chemical resistance information, refer to the ReadyToProcess WAVE 25 System Handbook, the … on the ground blackpinkWebReadyToProcess WAVE™ 25 system Xcellerex XDR 200 L bioreactor Xcellerex XDR 500 L bioreactor ... BioProcess™ NFF Pump System Virus reduction Xcellerex XDUO mixers … on the ground battle creekWebReadyToProcess Wave 25 Bioreactor Parameter ReadyToProcess WAVE 25 Rocker Dimensions 404 × 205 × 560 mm ... used. Manufacturer: Wave Biotech; The Wave Biotech Bioreactor System 2/10 EH P/N BASE2EH features a rocking base with integrated temperature control and has a rocking speed range of 3 - 40 rocks per minute along with … on the ground color codedWeb• ReadyToProcess™ WAVE 25 Rocker (GE Healthcare, Cat. No. 28988000) or comparable unit such as ... Prepare the WAVE system and pre-equilibrate culture medium (day –5): For these experiments, a Cellbag bioreactor rated to contain up to 10 L of culture was used. For a 10 L final culture volume, on the ground by roseWebSystem Bag size Min. Max. Tray ReadyToProcess WAVE 25 1 L 50 mL 500 mL N/A 2 L 100 mL 1 L Tray 20 10 L 500 mL 5 L Tray 20 20 L 1 L 10 L Tray 20 22 L 1 L 10 L Tray 50 50 L 5 L 25 L Tray 50 WAVE Bioreactor 200 100 L 5 L 50 L N/A 200 L 10 L 100 L N/A Table 4. Optical DO sensor specifications DO measurement range 0% to 250% air saturation ion television online live stream