Determine mass flow rate of refrigerant
Webh = heat of compression (Btu/lb) q = refrigerant circulated (lb/min) Compression Horsepower. Compression horsepower can be expressed as. P = W / 42.4 (2) where. P … WebWith all the enthalpies determined, the inner workings of the given cycle can be fully analyzed. First and most importantly, the calculation of the cycle’s power may occur. The …
Determine mass flow rate of refrigerant
Did you know?
WebThe mass flow rate of refrigerant is 5 kg/min. Determine (a) The compressor power, in kW (b) The refrigerating capacity, in tons. (c) The coefficient of performance. Solution: … Web(a) Calculate the steam mass flow rate (kg/s) through the boiler. (b) Compute the isentropic efficiency (%) of the adiabatic turbine. (c) Find the entropy generation (kW/K) for the adiabatic turbine. (d) Determine the total entropy generation (kW/K) for the condenser assuming heat transfer occurs to an environment of temperature 5 C.
WebThe refrigerant enters the condenser at 1.2 MPa and 50°C and leaves at the same pressure subcooled by 5°C. If the compressor consumes 3.3 kW of power, determine (a) the mass flow rate of the refrigerant, (b) the refrigeration load, (c) the COP, and (d) the minimum power input to the compressor for the same refrigeration load. WebNov 8, 2024 · The final mass flow unit is Kg / H, and when we calculate the suction pipe diameter, It is based on superheating, the density of the refrigerant is calculated in KGM3. The mass flow rate of the refrigerant divided by the density gives the volume flow rate at 1 point, in M3s. Finally, divide the volume flow rate by the cross-sectional area under ...
http://www.mhtl.uwaterloo.ca/courses/me354/tutorials/pdffiles/Winter07_quiz/q3t02_sol.pdf#:~:text=The%20mass%EF%AC%82ow%20rate%20of%20the%20refrigerant%20can%20be,temperature%20hw1%3D%20hf%4018%E2%97%A6C%3D75.54kJ%2Fkg%20hw2%3D%20hf%4026%E2%97%A6C%3D%20109.01kJ%2Fkg%20mR%28h2%CB%99%E2%88%92h3%29%20mR%28295.13%CB%99%E2%88%92111.37%29kJ%2Fkg WebThe rate of refrigeration of the cycle is to be 10.55 kW of refrigeration. Determine the coefficient of performance of the device as a refrigerator and the mass flow rate of R …
WebThe mass flow rate of the refrigerant was found to be 0.68 kg/s. The power input to the compressor was found to be 32.96 kJ/s. The mass flow rate of the cooling water was found to be 3.98 kg/s. The rate of exergy destruction associated with the compression process was found to be 7.84 kJ/s assuming a dead state temperature, T0, of 25 C.
WebAlso use Fundamentals of. (a)Determine the mass flow rate of refrigerant, in kg/s. (b)Determine compressor power in kW. (c)calculate coefficient of performance (use answer of part b to help you out.) Also … fizbans dragonborn breathWebMar 23, 2024 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... cannon gun safe battery deadWebSince no mass flow rate of the refrigerant has been provided, the entire analysis is done in terms of specific energy values. Notice that the same system can be used either for a refrigerator or air conditioner, in which the heat absorbed in the evaporator (q evap ) is the desired output, or for a heat pump, in which the heat rejected in the ... fizbans alternate coverWebi.e., the flow of mass m through a surface per unit time t.. The overdot on the m is Newton's notation for a time derivative.Since mass is a scalar quantity, the mass flow rate (the … fizbans featsWebIt is specified that the temperature rise of the water not exceed $4^{\circ} \mathrm{C}$ The power dissipation of the box is $2 \mathrm{kW}$, which is removed entirely by water. If the box operates 24 hours a day, 365 days a year, determine the mass flow rate of water flowing through the box and the amount of cooling water used per year. cannon green princeton universityWebSep 23, 2024 · Method to Calculate the Refrigerant Mass Flow Rate. 3.1. Validation of Adiabatic Process Hypothesis in the Expansion Phase and Compression Phase. As … fizbans anyflipWebcompression refrigeration cycle between 0.14 and 0.8 MPa. If the mass flow rate of the refrigerant is 0.05 kg/s, determine the rate of heat removal from the refrigerated space and the power input to the compressor, the heat rejection rate to the environment, and the COP of the refrigerator. Setting Up the Problem age 5.712.5 cannon gun safe changing battery